MURAL - Maynooth University Research Archive Library



    Development of a distributed, fully automated, bidirectional telemetry system for amperometric microsensor and biosensor applications


    Rocchitta, Gaia, Migheli, Rossana, Dedola, Sonia, Calia, Giammario, Desole, Maria S., Lowry, John P., O'Neill, Robert D. and Serra, Pier A. (2007) Development of a distributed, fully automated, bidirectional telemetry system for amperometric microsensor and biosensor applications. Sensors and Actuators B: Chemical, 126 (2). pp. 700-709. ISSN 0925-4005

    [thumbnail of JL-Development-2007.pdf]
    Preview
    Text
    JL-Development-2007.pdf

    Download (1MB) | Preview

    Abstract

    A new bidirectional telemetry system for amperometric sensor applications has been developed. A fully automated peripheral unit (PU), constituted by a potentiostat, a two-channel I/V converter, a microcontroller unit (MCU) and a signal transmitter, was designed, constructed, and tested. A peripheral interface controller (PIC) MCU drives a digital-to-analog converter (DAC), which polarized the sensor, while the resulting anodic current is converted to a digital value by an analog-to-digital converter (ADC). The PIC firmware is developed in assembly and transferred to the MCU through a bootloader algorithm. The digital data are sent to a personal computer using a 4-byte packet protocol by means of a miniaturized 433 MHz frequency modulation (FM) transceiver with a linear range up to 200 m. The central unit (CU) is connected to a PC via Universal Serial Bus (USB). Custom developed software, implemented in Basic and C, allows the PC to control several PUs and record, plot and handle received data. The development and operation of the hardware and software are described. The system performance was evaluated using an automated dummy cell connected to the PU. The amperometric response of nitric oxide (NO), dopamine (DA) microsensors and a glucose biosensor was determined in vitro. This apparatus serves as a basic model to realize an in vivo bidirectional telemetry system built with standard components readily available at low cost.
    Item Type: Article
    Keywords: Potentiostat; Amperometry; Microcontroller; Microsensor; Biosensor; Biotelemetry;
    Academic Unit: Faculty of Science and Engineering > Chemistry
    Item ID: 8039
    Identification Number: 10.1016/j.snb.2007.04.019
    Depositing User: John Lowry
    Date Deposited: 22 Mar 2017 16:48
    Journal or Publication Title: Sensors and Actuators B: Chemical
    Publisher: Elsevier
    Refereed: Yes
    Related URLs:
    URI: https://mu.eprints-hosting.org/id/eprint/8039
    Use Licence: This item is available under a Creative Commons Attribution Non Commercial Share Alike Licence (CC BY-NC-SA). Details of this licence are available here

    Repository Staff Only (login required)

    Item control page
    Item control page

    Downloads

    Downloads per month over past year

    Origin of downloads