MURAL - Maynooth University Research Archive Library



    An Electrochemical Evaluation of Novel Ferrocene Derivatives for Glutamate and Liver Biomarker Biosensing


    Soon, Geok Hong, Deasy, Mary and Dempsey, Eithne (2021) An Electrochemical Evaluation of Novel Ferrocene Derivatives for Glutamate and Liver Biomarker Biosensing. Biosensors, 11 (8). p. 254. ISSN 2079-6374

    [thumbnail of EithneDempseyElec2021.pdf]
    Preview
    Text
    EithneDempseyElec2021.pdf

    Download (7MB) | Preview

    Abstract

    Here, we present an evaluation of two new monosubstituted ferrocene (Fc) derivatives, 3- (1H-pyrrol-1-yl)propanamidoferrocene and 1-hydroxy-2-[2-(thiophen-3-yl)-ethylamino]ethylferrocene, as glutamate oxidase mediators, together with their preparation and characterisation. Taking into consideration the influence of the electronic effects of substituents on the redox potentials of the Fc species, two candidates with pyrrole or thiophene moieties were proposed for investigation. Film studies involved potential sweeping in the presence of pyrrole or 3,4-ethylenedioxythiophene monomers resulting in stable electroactive films with % signal loss upon cycling ranging from 1 to 7.82% and surface coverage (Γ) 0.47–1.15 × 10−9 mol/cm2 for films formed under optimal conditions. Construction of a glutamate oxidase modified electrode resulted in second-generation biosensing with the aid of both cyclic voltammetry and hydrodynamic amperometry, resulting in glutamate sensitivity of 0.86–1.28 µA/mM and Km (app) values over the range 3.67–5.01 mM. A follow-up enzyme assay for liver biomarker γ-glutamyl transpeptidase realised unmediated and mediated measurement establishing reaction and incubation time investigations and a realising response over <100 U/L γ-glutamyl transpeptidase with a sensitivity of 5 nA/UL−1
    Item Type: Article
    Additional Information: Cite as: Soon, G.H.; Deasy, M.; Dempsey, E. An Electrochemical Evaluation of Novel Ferrocene Derivatives for Glutamate and Liver Biomarker Biosensing. Biosensors 2021, 11, 254. https://doi.org/10.3390/bios11080254
    Keywords: glutamate biosensor; liver biomarker; γ-glutamyl transpeptidase; electrochemical sensing; ferrocenes; polymer
    Academic Unit: Faculty of Science and Engineering > Chemistry
    Faculty of Science and Engineering > Research Institutes > Human Health Institute
    Item ID: 17380
    Identification Number: 10.3390/bios11080254
    Depositing User: Eithne Dempsey
    Date Deposited: 06 Jul 2023 09:41
    Journal or Publication Title: Biosensors
    Publisher: MDPI
    Refereed: Yes
    Related URLs:
    URI: https://mu.eprints-hosting.org/id/eprint/17380
    Use Licence: This item is available under a Creative Commons Attribution Non Commercial Share Alike Licence (CC BY-NC-SA). Details of this licence are available here

    Repository Staff Only (login required)

    Item control page
    Item control page

    Downloads

    Downloads per month over past year

    Origin of downloads